dc.description.abstractLong-span timber floor elements increase the flexibility of a building and exhibit a significant market potential. Timber floor elements are endeavouring to fulfil this potential, but building projects employing long-span timber floors have encountered drawbacks. High costs and vibration performance are challenging, and the timber industry is under substantial pressure to find attractive solutions for building components with otherwise favourable environmental features. Only a few existing studies have investigated serviceability sensitivity in relation to timber floor connections. Interconnections are inexpensive to produce and install and may offer a resource-efficient approach to improving serviceability performance. In the present study, the effect of interconnections is investigated in a full-scale structural test. Floor elements positioned in different configurations have been tested for static and dynamic performance using different types of interconnections. The observed effects of interconnection types vary according to the configuration and direction of mode shapes, and are assessed in terms of shift in frequency, damping and resonant energy. These can all be utilised in combination with observed differences in the deflection parameter. The present work demonstrates that connections between timber elements have significant effects on timber floor serviceability and may offer interesting solutions to improve the vibration performance of long-span timber floors.en_US
dc.language.isoengen_US
dc.publisherSpringer Natureen_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleEffects of interconnections between timber floor elements: dynamic and static evaluations of structural scale testsen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.source.journalEuropean Journal of Wood and Wood Productsen_US
dc.identifier.doihttps://doi.org/10.1007/s00107-021-01709-y
dc.identifier.cristin1909485
dc.relation.projectNorges forskningsråd: 254699en_US
dc.description.localcodeThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.en_US
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Navngivelse 4.0 Internasjonal
Except where otherwise noted, this item's license is described as Navngivelse 4.0 Internasjonal