Vis enkel innførsel

dc.contributor.authorNitter, Therese Bergh
dc.contributor.authorSvendsen, Kristin V Hirsch
dc.date.accessioned2020-08-21T11:06:27Z
dc.date.available2020-08-21T11:06:27Z
dc.date.created2020-03-18T14:48:30Z
dc.date.issued2020
dc.identifier.citationScience of the Total Environment. 2020, 723 .en_US
dc.identifier.issn0048-9697
dc.identifier.urihttps://hdl.handle.net/11250/2673391
dc.description.abstractThe association between asthma and exposure to the air in swimming facilities has been acknowledged. However, the variation in, long-term exposure to and management of the respiratory irritant trichloramine (NCl3) is not well understood. In this study, 313 swimmers above 18 years of age licensed by the Norwegian Swimming Association answered a questionnaire about health and swimming. The prevalence of asthma amongst the most-exposed swimmers was 36%. Two facilities, those with the highest and lowest reported prevalence of asthma, were chosen for further investigation. For each facility, a one-week-long monitoring campaign was performed, during which pool management, air and water quality were investigated. The results of this study showed that time of day, occupancy and pool management affect the concentration of NCl3, which ranged from 58 μg/m3 to 461 μg/m3. Furthermore, in one of the facilities, the concentration of CO2 was measured to evaluate whether this contaminant could be used to predict the number of pool occupants as well as the concentration of NCl3 in the air. The concentration of CO2 was significantly correlated with occupancy level (ρ = 0.82, p = 0.01) and NCl3 concentration (r = 0.80, p = 0.01). Furthermore, according to the random intercept model the concentration of CO2 explained 52% of the variation observed in the air concentration of NCl3. CO2 sensors to control the air supply can help reduce the air concentrations of NCl3 and balance the air supply based on occupancy level.en_US
dc.language.isoengen_US
dc.publisherElsevieren_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleCovariation amongst pool management, trichloramine exposure and asthma for swimmers in Norwayen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.source.pagenumber9en_US
dc.source.volume723en_US
dc.source.journalScience of the Total Environmenten_US
dc.identifier.doi10.1016/j.scitotenv.2020.138070
dc.identifier.cristin1802259
dc.description.localcodeThis is an open access article distributed under the terms of the Creative Commons CC-BY license, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.en_US
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode2


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse 4.0 Internasjonal