Vis enkel innførsel

dc.contributor.authorGajic, Darija
dc.contributor.authorStupar, Diana
dc.contributor.authorAntunovic, Biljana
dc.contributor.authorJankovic, Aleksandar
dc.date.accessioned2020-04-23T08:24:07Z
dc.date.available2020-04-23T08:24:07Z
dc.date.created2019-10-28T09:30:34Z
dc.date.issued2019
dc.identifier.citationEnergy and Buildings. 2019, 204:109511 1-14.en_US
dc.identifier.issn0378-7788
dc.identifier.urihttps://hdl.handle.net/11250/2652186
dc.description.abstractResearch analyzed the influence of parameters derived from urban planning, architecture, building materials and technology, building physics, users and patterns of use, the measured thermal performance of the envelope and thermal comfort parameters on the energy performance indicators of two representative kindergartens. The paper presents an energy performance indicator through design and measured parameters of representative samples of old and new kindergartens located in the temperate climate zone of Banja Luka (northern Bosnia and Herzegovina). When the data presented in EN 13790 concerning the patterns of use and design temperatures for residential buildings or educational and cultural buildings is compared with the measured, surveyed, analyzed and estimated kindergarten data, the design parameters are found to deviate from the measured parameters. On the basis of the presented analysis, it is recommended that measurement of the thermal performance of envelopes of old buildings become a mandatory part of energy audit, and that an appropriate set of parameter values be used in the calculation of the energy performance indicator of kindergartens. Kindergartens must be introduced as a specific type of buildings in policies related to the minimum requirements for the energy performance of buildings and rational use of energy, energy audit and certification of buildings.en_US
dc.language.isoengen_US
dc.publisherElsevieren_US
dc.titleDetermination of the energy performance indicator of kindergartens through design, measured and recommended parametersen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.source.pagenumber1-14en_US
dc.source.volume204:109511en_US
dc.source.journalEnergy and Buildingsen_US
dc.identifier.doi10.1016/j.enbuild.2019.109511
dc.identifier.cristin1741015
dc.description.localcodeThis article will not be available due to copyright restrictions (c) 2019 by Elsevieren_US
cristin.unitcode194,61,55,0
cristin.unitnameInstitutt for arkitektur og teknologi
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode2


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel