dc.description.abstractBackground Out-of-hospital cardiac arrest (OHCA) is a critical incident with a high mortality rate. Augmentation of the circulation during cardiopulmonary resuscitation (CPR) might be beneficial. Use of resuscitative endovascular balloon occlusion of the aorta (REBOA) redistribute cardiac output to the organs proximal to the occlusion. Preclinical data support that patients in non-traumatic cardiac arrest might benefit from REBOA in the thoracic level during CPR. This study describes a training programme to implement the REBOA procedure to a prehospital working team, in preparation to a planned clinical study. Methods We developed a team-based REBOA training programme involving the physicians and paramedics working on the National Air Ambulance helicopter base in Trondheim, Norway. The programme consists of a four-step approach to educate, train and implement the REBOA procedure in a simulated prehospital setting. An objective structured assessment of prehospital REBOA application scoring chart and a special designed simulation mannequin was made for this study. Results Seven physicians and 3 paramedics participated. The time needed to perform the REBOA procedure was 8.5 (6.3–12.7) min. The corresponding time from arrival at scene to balloon inflation was 12.0 (8.8–15) min. The total objective assessment scores of the candidates’ competency was 41.8 (39–43.5) points out of 48. The advanced cardiovascular life support (ACLS) remained at standard quality, regardless of the simultaneous REBOA procedure. Conclusion This four-step approach to educate, train and implement the REBOA procedure to a prehospital working team ensures adequate competence in a simulated OHCA setting. The use of a structured training programme and objective assessment of skills is recommended before utilising the procedure in a clinical setting. In a simulated setting, the procedure does not add significant time to the prehospital resuscitation time nor does the procedure interfere with the quality of the ACLS.nb_NO
dc.language.isoengnb_NO
dc.publisherBMJ Journalsnb_NO
dc.rightsNavngivelse-Ikkekommersiell 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/deed.no*
dc.titleResuscitative endovascular balloon occlusion of the aorta (REBOA) in non-traumatic out-of-hospital cardiac arrest: Evaluation of an educational programmenb_NO
dc.typeJournal articlenb_NO
dc.typePeer reviewednb_NO
dc.description.versionpublishedVersionnb_NO
dc.source.pagenumber1-8nb_NO
dc.source.volume9:e027980nb_NO
dc.source.journalBMJ Opennb_NO
dc.source.issue5nb_NO
dc.identifier.doi10.1136/bmjopen-2018-027980
dc.identifier.cristin1724443
dc.description.localcodeThis is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/.nb_NO
cristin.unitcode194,65,25,0
cristin.unitcode1920,29,0,0
cristin.unitcode1920,28,0,0
cristin.unitcode1920,4,0,0
cristin.unitcode194,64,92,0
cristin.unitnameInstitutt for sirkulasjon og bildediagnostikk
cristin.unitnameKlinikk for akutt- og mottaksmedisin
cristin.unitnameKlinikk for anestesi og intensivmedisin
cristin.unitnameKlinikk for bildediagnostikk
cristin.unitnameInstitutt for maskinteknikk og produksjon
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Navngivelse-Ikkekommersiell 4.0 Internasjonal
Except where otherwise noted, this item's license is described as Navngivelse-Ikkekommersiell 4.0 Internasjonal