Vis enkel innførsel

dc.contributor.authorAguwa, Celestine
dc.contributor.authorMonplaisir, Leslie
dc.contributor.authorTurgut, Ozgu
dc.contributor.authorJordan, Will
dc.contributor.authorEtu, Egbe-Etu
dc.date.accessioned2020-02-03T10:27:57Z
dc.date.available2020-02-03T10:27:57Z
dc.date.created2019-09-25T11:10:42Z
dc.date.issued2019
dc.identifier.citationCogent Engineering. 2019, 6 (1)nb_NO
dc.identifier.issn2331-1916
dc.identifier.urihttp://hdl.handle.net/11250/2639232
dc.description.abstractThe reprocessing of reusable medical equipment (RME) is complex due to the difficulty of eliminating infections. Healthcare providers have expressed dissatisfaction with the difficulty faced in cleaning and disinfecting medical equipment after use. Reprocessed RMEs include endoscopes, valves, adapters etc. This research aims to increase the ease of reprocessing and decrease the risk of infection using a collaborative modular architecture framework. The methodology is divided into four steps. First, we identify and define the product’s functional and physical decompositions. Secondly, based on stakeholders’ input, parameters such as design, human factors, and cost were identified to be the main factors affecting the reprocessing of an endoscope. The parameters’ subsequent metrics are selected for performance requirements. Thirdly, surveys are developed to collect data about the performance of different endoscope models. Fourthly, we utilize a linear multi-objective optimization model which aims at generating representative solutions on the true Pareto front of the problem that maximizes the similarity among module members in terms of the factors. Finally, we combine the module information with efficiency feedback to derive recommendations for the users. A case study is presented using hospital data. The results indicate that there is a high risk of infection caused by human errors during reprocessing for endoscopes clustered in Module 1 compared to Module 2 and 3. To ensure that the safety and quality of medical care rendered to patients are not compromised, we recommend that healthcare providers utilize endoscopes in Modules 2 and 3 as they are safe and easy to reprocess.nb_NO
dc.language.isoengnb_NO
dc.publisherCogent OA, part of the Taylor & Francis Groupnb_NO
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleDesign for reusability of medical equipment for optimal modularization using an endoscope as case studynb_NO
dc.typeJournal articlenb_NO
dc.typePeer reviewednb_NO
dc.description.versionpublishedVersionnb_NO
dc.source.volume6nb_NO
dc.source.journalCogent Engineeringnb_NO
dc.source.issue1nb_NO
dc.identifier.doi10.1080/23311916.2019.1636516
dc.identifier.cristin1728772
dc.description.localcode© 2019 The Author(s). This open access article is distributed under a Creative Commons Attribution (CC-BY) 4.0 license.nb_NO
cristin.unitcode194,60,25,0
cristin.unitnameInstitutt for industriell økonomi og teknologiledelse
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse 4.0 Internasjonal