Vis enkel innførsel

dc.contributor.advisorEgenes, Jan Steinar
dc.contributor.authorBertelsen, Kjartan
dc.contributor.authorTollefsen, Marcus Levin
dc.date.accessioned2019-10-18T14:00:17Z
dc.date.available2019-10-18T14:00:17Z
dc.date.issued2019
dc.identifier.urihttp://hdl.handle.net/11250/2623130
dc.description.abstractDenne bacheloroppgaven har som hovedfokus å vurdere hvor egnet tidstemperaturkurven for en standardbrann (ISO-834) er til å dokumentere bæreevnen til bygninger i brannklasse 3, som er oppført av eksponerte KLT-elementer. Dette gjør vi ved å sammenligne testbranner i KLT hvor brannforløpet går fritt, med standardbranner. Gjennom en litteraturstudie ble relevant nyere forskning gjennomgått for å kartlegge hvordan en rombrann som er bygget opp av KLT, vil utarter seg. Vi satte oss grundig inn i hvilke faktorer som er styrende for et naturlig brannforløp i KLT, slik at vi kunne gjøre en vurdering på om det finnes forskjeller i den totale innbrenningen, temperaturutviklingen og om bruken av KLT hadde innvirkning på tidsforløpet frem til en eventuell selvslukking. Funnene ble så systematisert og sammenlignet med brannforløpet til en standardbrann som er beskrevet i ISO 834. Litteraturstudiet avdekket at det er til dels store sprik mellom innbrenningshastigheter som måles i et naturlig brannforløp og en ISO brann, og at det er store usikkerheter knyttet til om en rombrann med flere enn to eksponerte sider vil selvslukke. Graden av delaminering er her en avgjørende faktor, da delaminering kan føre til at brannen tar seg opp igjen slik at man kan få flere overtenninger med påfølgende fullt utviklede rombranner og et tidsforløp som går langt utover det som konstruksjonen er dimensjonert for å tåle. Det er også avdekket at det ikke nødvendigvis er høyest mulig temperatur i brannrommet som er den mest kritiske faktoren, men tiden til en eventuell selvslukking inntreffer som er avgjørende for om man får en kollaps eller ikke. Summen av disse faktorene viser at tidstemperaturkurven til ISO 834 i mange tilfeller ikke gir et godt nok bilde av virkelige brannsituasjoner, og dermed ikke er egnet for branndimensjonering av bygg hvor det er flere eksponerte brennbare flater. I reelle storbranner er vind og naturlig trekk kritiske faktorer, så vi hadde forventet at det skulle eksistere litteratur og forskning på temaet om hvilken påvirkning tvungen ventilasjon hadde på innbrenningshastigheten og varmeproduksjonen. Det viste seg at dette temaet, uvisst av hvilken grunn var nesten helt fraværende i forskningslitteraturen.
dc.description.abstractThe main focus of this bachelor degree thesis is to assess the suitability of the time temperature curve for a standard fire, in accordance with ISO-834, and to document the load bearing capacity of fire class 3 buildings where Cross Laminated Timber (CLT) has been used. This is achieved by comparing the fire test results from a free cycle test with those from a standard temperature-temperature curve. A literature review of relevant research papers allowed the mapping of how a fire develops once ignited in a compartment constructed from CLT. This allowed us to determine whether there were differences in total burn time, temperature variations and whether or not the use of CLT had an impact on the length of time to self-extinguishment. The findings were then tabulated and compared to the cycle of a standard fire as described in ISO 834. The literature review revealed that there are, in part, large gaps between the charring rates when measured in a natural fire cycle and those from a standard ISO fire. In addition, there are large uncertainties associated with whether a compartment fire, with more than two exposed sides, will actually self-extinguish. The degree of delamination, of CLT during the fire, is the decisive factor as delamination can cause new growth period within subsequent fully developed fires, and a time lapse that goes far beyond what the construction is expected to endure. It is also revealed that it is not necessarily the maximum temperature in the fire zone that is the most critical factor, rather, it is the time to self-extinguishment that is essential for determining if there will be a collapse or not. The sum of all these factors indicates that the standard time temperature curve of ISO 834, in many cases, does not provide an accurate enough representation of real fire situations. Thus, it is not suitable for fire sizing of buildings where there are several exposed flammable surfaces. In all major fires, wind and natural draw are both critical factors, so we had expected that through the course of our literature review there would be sufficient research available on the impact that enforced ventilation had on burn-in rates and heat production. However, it turned out that this subject matter, for whatever reason, was almost entirely absent in any available research literature.
dc.languagenob
dc.publisherNTNU
dc.titleVurdering av standardisert tid-temperaturkurvers relevans i forbindelse med branndimnesjonering av høye trehus.
dc.typeBachelor thesis


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel