dc.identifier.urihttp://hdl.handle.net/11250/2617969
dc.description.abstractExperimental investigation of transcritical R744 pack for Indian supermarkets was performed. Parallel combination of expansion work recovery multiejector blocks was applied for optimization of energy performance of the whole pack. The discharge pressure control proved to be fully functional with parallel multiejector operation providing system stability over a broad range of ambient conditions. Energy performance of the pack measured in Indian conditions was at the level recorded in the NTNU/SINTEF laboratory for a reference R744 pack. High ambient temperatures might result in operation on the verge of the operational envelope for compressor discharge temperature, especially for the MT machines.nb_NO
dc.language.isoengnb_NO
dc.publisherInternational Institute of Refrigerationnb_NO
dc.relation.ispartof25th IIR International Congress of Refrigeration Proceedings
dc.titleExperimental investigation of CO2 systems for Indian supermarkets with parallel configuration of multiejectors (INDEE)nb_NO
dc.typeChapternb_NO
dc.description.versionacceptedVersionnb_NO
dc.identifier.doi10.18462/iir.icr.2019.0797
dc.identifier.cristin1724305
dc.description.localcodeThis chapter will not be available due to copyright restrictions (c) 2019 by International Institute of Refrigerationnb_NO
cristin.unitcode194,64,25,0
cristin.unitnameInstitutt for energi- og prosessteknikk
cristin.ispublishedtrue
cristin.fulltextpostprint
cristin.qualitycode1