dc.description.abstractRapporten har til hensikt å undersøke en lavblokk i tre fra byggefirma BoligPartner. De ønsker å få utredet byggverkets avstivningssystem. De ønsket spesielt å få undersøkt om det ville være mulig å fjerne en eller flere avstivende vegger for større versatilitet i planløsningen. Problemstilling: “Designe avstivningssystem for gitt lavblokk i tre med fokus på i hvilken grad det er mulig å fjerne en eller flere avstivende innervegger for å kunne få en mest mulig åpen planløsning.” Rapporten er begrenset til å omhandle avstivningssystemet og alle komponentene som er involvert i kraftoverføring mellom påkjent yttervegg og fundament. Det ble sett på fire ulike scenarioer med variasjoner i plasseringen av avstivende komponenter. Disse ble vurdert opp mot hverandre for å avgjøre hvilke som er best egnet til å ta horisontale laster. Det ble besluttet å ikke undersøke svingninger eller seismiske laster i dette byggverket. Kraftfordeling på avstivningssystemet ble beregnet i henhold til Betongelementhåndboka. Metoden ble endret for å ta høyde for at de avstivende komponentene er av forskjellige materialer med ulik geometri. Avstivningssystemene med kraftoverførende komponenter er dimensjonert i sin helhet i henhold til Eurokode. Dette omfatter betongskiver, fagverk, forbindelser, dekkeskiver og fundament. Av de fire scenarioene som ble dimensjonert, anses scenario 4 som best egnet til å avstive byggverket. Dette scenarioet overholder kravene som er satt om kapasitetsutnyttelse og deformasjon.
dc.description.abstractThis study is intended to investigate a wooden low-rise building from the construction company BoligPartner. They want to investigate the constructions bracing system. In particular they wanted to investigate whether it would be possible to remove one or more shear walls for greater versatility in the floor plan. Topic question: "Design the bracing system of a given wooden low-rise building focusing on the extent to which it is possible to remove one or more inner shear walls to get the most open floor plan." The report is limited to addressing the bracing system and all components involved in the transmission of forces between the wind exposed exterior walls and the foundation. Four different scenarios were compiled with variations in the positioning of the bracing components. These were assessed against each other to determine which ones are best suited to take horizontal loads. It was decided not to investigate fluctuations or seismic loads in this study. Force distribution on the bracing system was calculated according to a method provided by the Norwegian manufacturing of concrete elements for construction industry. The method was modified to consider that the bracing components are of different materials with different geometries. The bracing systems with force-transmitting components are calculated in their entirety according to the Eurocode. This includes concrete shear walls, trusses, connections, floor slabs and foundations. Of the four scenarios considered, scenario 4 was found to be best suited to brace the construction. This scenario meets the requirements of capacity utilization and deformation.
dc.languagenob
dc.publisherNTNU
dc.titleKombinert avstivningssystem for lavblokker i tre
dc.typeBachelor thesis


Tilhørende fil(er)

FilerStørrelseFormatVis

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel