Vis enkel innførsel

dc.contributor.authorBaasland, Ingrid
dc.date.accessioned2019-04-11T06:03:20Z
dc.date.available2019-04-11T06:03:20Z
dc.date.created2019-02-15T15:14:35Z
dc.date.issued2019
dc.identifier.issn1932-6203
dc.identifier.urihttp://hdl.handle.net/11250/2594109
dc.description.abstractAnyplex II HPV28 (`Anyplex`) is a semi-quantitative DNA PCR assay divided into set A, comprising 14 high risk (hr)HPV types; and set B, comprising 5 possibly hrHPV types and 9 low risk (lr)HPV types. We compared the ability of Anyplex to that of Hybrid Capture 2 (HC2) and PreTect HPV-Proofer (`Proofer`) to detect cervical intraepithelial neoplasia grade two or worse (CIN2+) by HPV types and viral load. This cross-sectional study included 296 women referred to colposcopy with abnormal cervical cytology and/or persistent HPV infection. CIN2+ was identified in 175/296 women. Liquid based cytology samples were used to perform HPV testing. The sensitivity of Anyplex to detect CIN2+ was 98.9% (95% CI 95.9–99.9) and specificity 43.0% (95% CI 34.0–52.3). Restricting to medium and high viral loads in Anyplex set A, sensitivity and specificity were 97.1% (95% CI 93.5–99.1) and 59.5% (95% CI 50.2–68.3) with positive (PPV) and negative predictive value (NPV) 77.6% and 93.5%, respectively, comparable to HC2. Restricting Anyplex to the hrHPV types in Proofer, HPV16, 18, 31, 33 and 45, sensitivity and specificity for CIN2+ were 85.1% (95% CI 79.0–90.1) and 71.1% (95% CI 62.1–79.0), comparable to Proofer`s. When adding HPV52 and 58, the sensitivity for CIN2+ was 92.6% (95% CI 87.6–96.0) and CIN3+ 96.5% (95% CI 92.0–98.8). No value of Anyplex set B was found in detecting CIN2+. In conclusion, the clinical performance of medium and high viral loads in Anyplex set A was comparable to HC2. Restricting the test to the 7 hrHPV types included in the 9-valent HPV-vaccine, HPV16, 18, 31, 33, 45, 52 and 58, satisfies the international criteria for cervical cancer screening with relative sensitivity compared to HC2 for CIN2+ and CIN3+ of 0.98 and 1.01, respectively. Detecting all 28 Anyplex HPV types adds no benefit in a referral population.nb_NO
dc.language.isoengnb_NO
dc.publisherPublic Library of Science (PLOS)nb_NO
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleClinical performance of Anyplex II HPV28 by human papillomavirus type and viral load in a referral populationnb_NO
dc.typeJournal articlenb_NO
dc.typePeer reviewednb_NO
dc.description.versionpublishedVersionnb_NO
dc.source.journalPLoS ONEnb_NO
dc.identifier.doi10.1371/journal.pone.0210997
dc.identifier.cristin1677792
dc.description.localcodeOpen Access. Research accepted by PLOS journals is published under a CC BY license. Anyone may reuse the article with proper attribution.nb_NO
cristin.unitcode194,65,20,0
cristin.unitnameInstitutt for samfunnsmedisin og sykepleie
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse 4.0 Internasjonal