Show simple item record

dc.contributor.authorBaasland, Ingrid
dc.date.accessioned2019-04-11T06:03:20Z
dc.date.available2019-04-11T06:03:20Z
dc.date.created2019-02-15T15:14:35Z
dc.date.issued2019
dc.identifier.issn1932-6203
dc.identifier.urihttp://hdl.handle.net/11250/2594109
dc.description.abstractAnyplex II HPV28 (`Anyplex`) is a semi-quantitative DNA PCR assay divided into set A, comprising 14 high risk (hr)HPV types; and set B, comprising 5 possibly hrHPV types and 9 low risk (lr)HPV types. We compared the ability of Anyplex to that of Hybrid Capture 2 (HC2) and PreTect HPV-Proofer (`Proofer`) to detect cervical intraepithelial neoplasia grade two or worse (CIN2+) by HPV types and viral load. This cross-sectional study included 296 women referred to colposcopy with abnormal cervical cytology and/or persistent HPV infection. CIN2+ was identified in 175/296 women. Liquid based cytology samples were used to perform HPV testing. The sensitivity of Anyplex to detect CIN2+ was 98.9% (95% CI 95.9–99.9) and specificity 43.0% (95% CI 34.0–52.3). Restricting to medium and high viral loads in Anyplex set A, sensitivity and specificity were 97.1% (95% CI 93.5–99.1) and 59.5% (95% CI 50.2–68.3) with positive (PPV) and negative predictive value (NPV) 77.6% and 93.5%, respectively, comparable to HC2. Restricting Anyplex to the hrHPV types in Proofer, HPV16, 18, 31, 33 and 45, sensitivity and specificity for CIN2+ were 85.1% (95% CI 79.0–90.1) and 71.1% (95% CI 62.1–79.0), comparable to Proofer`s. When adding HPV52 and 58, the sensitivity for CIN2+ was 92.6% (95% CI 87.6–96.0) and CIN3+ 96.5% (95% CI 92.0–98.8). No value of Anyplex set B was found in detecting CIN2+. In conclusion, the clinical performance of medium and high viral loads in Anyplex set A was comparable to HC2. Restricting the test to the 7 hrHPV types included in the 9-valent HPV-vaccine, HPV16, 18, 31, 33, 45, 52 and 58, satisfies the international criteria for cervical cancer screening with relative sensitivity compared to HC2 for CIN2+ and CIN3+ of 0.98 and 1.01, respectively. Detecting all 28 Anyplex HPV types adds no benefit in a referral population.nb_NO
dc.language.isoengnb_NO
dc.publisherPublic Library of Science (PLOS)nb_NO
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleClinical performance of Anyplex II HPV28 by human papillomavirus type and viral load in a referral populationnb_NO
dc.typeJournal articlenb_NO
dc.typePeer reviewednb_NO
dc.description.versionpublishedVersionnb_NO
dc.source.journalPLoS ONEnb_NO
dc.identifier.doi10.1371/journal.pone.0210997
dc.identifier.cristin1677792
dc.description.localcodeOpen Access. Research accepted by PLOS journals is published under a CC BY license. Anyone may reuse the article with proper attribution.nb_NO
cristin.unitcode194,65,20,0
cristin.unitnameInstitutt for samfunnsmedisin og sykepleie
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Navngivelse 4.0 Internasjonal
Except where otherwise noted, this item's license is described as Navngivelse 4.0 Internasjonal