dc.description.abstractThree common piezoelectric materials have been studied for use in pulsed wave Doppler ultrasound, where high sensitivity is required, while bandwidth is less important. A large transducer aperture, 80 mm 2 , results in a low electrical impedance, making the transducers challenging to drive with conventional electronics and cables. Air-backed transducers with electrical tuning circuitry and cable assembly were made using the piezoelectric materials Pz24, Pz27, and Pz29. Pz24 is a hard PZT, with dielectric constant of 240, the other materials are soft PZT with dielectric constants around 1000. It was found that the transducer made with Pz24 gave 2 dB better two-way sensitivity compared to those made with the other PZT-variants. The improved performance is explained by the higher electrical impedance from using pz24nb_NO
dc.language.isoengnb_NO
dc.publisherInstitute of Electrical and Electronics Engineers (IEEE)nb_NO
dc.titleDesign, Fabrication and Testing Highly Sensitive Single Element Doppler Transducersnb_NO
dc.typeJournal articlenb_NO
dc.typePeer reviewednb_NO
dc.description.versionacceptedVersionnb_NO
dc.source.pagenumber4nb_NO
dc.source.journalProceedings - IEEE Ultrasonics Symposiumnb_NO
dc.identifier.doi10.1109/ULTSYM.2018.8580164
dc.identifier.cristin1674875
dc.relation.projectNorges forskningsråd: 237887nb_NO
dc.relation.projectNorges forskningsråd: 245963nb_NO
dc.description.localcode© 2018 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.nb_NO
cristin.unitcode194,65,25,0
cristin.unitnameInstitutt for sirkulasjon og bildediagnostikk
cristin.ispublishedtrue
cristin.fulltextpostprint
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel