Vis enkel innførsel

dc.contributor.authorRomijn, Elisabeth Inge
dc.contributor.authorFinnøy, Andreas
dc.contributor.authorKumar, Rajesh
dc.contributor.authorLilledahl, Magnus Borstad
dc.date.accessioned2019-01-30T11:45:32Z
dc.date.available2019-01-30T11:45:32Z
dc.date.created2018-09-18T13:28:37Z
dc.date.issued2018
dc.identifier.issn1932-6203
dc.identifier.urihttp://hdl.handle.net/11250/2583071
dc.description.abstractPolarization-resolved second harmonic generation (P-SHG) microscopy has evolved as a promising technique to reveal subresolution information about the structure and orientation of ordered biological macromolecules. To extend the adoption of the technique, it should be easily integrated onto commercial laser scanning microscopes. Furthermore, procedures for easy calibration and assessment of measurement accuracy are essential, and measurements should be fully automated to allow for analysis of large quantities of samples. In this paper we present a setup for P-SHG which is readily incorporated on commercial multiphoton microscopes. The entire system is completely automated which allows for rapid calibration through the freely available software and for automated imaging for different polarization measurements, including linear and circular polarization of the excitation beam. The results show that calibration settings are highly system dependent. We also show that the accuracy of the polarization control is easily quantified and that it varies between systems. The accuracy can be tuned by iterative alignment of optics or a more fine-grained calibration procedure. Images of real samples show that the red accuracy of the results is easily visualized with the automated setup. Through this system we believe that P-SHG could develop a wider adoption in biomedical applications.nb_NO
dc.language.isoengnb_NO
dc.publisherPublic Library of Sciencenb_NO
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleAutomated calibration and control for polarization resolved second harmonic generation on commercial microscopesnb_NO
dc.title.alternativeAutomated polarization-resolved second harmonic generation imagingnb_NO
dc.typeJournal articlenb_NO
dc.typePeer reviewednb_NO
dc.description.versionpublishedVersionnb_NO
dc.source.volume13nb_NO
dc.source.journalPLoS ONEnb_NO
dc.source.issue4nb_NO
dc.identifier.doi10.1371/journal.pone.0195027
dc.identifier.cristin1610590
dc.description.localcodeCopyright: © 2018 Romijn et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.nb_NO
cristin.unitcode194,67,80,0
cristin.unitcode194,63,55,0
cristin.unitcode194,66,20,0
cristin.unitnameInstitutt for lærerutdanning
cristin.unitnameInstitutt for IKT og realfag
cristin.unitnameInstitutt for fysikk
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse 4.0 Internasjonal