Vis enkel innførsel

dc.contributor.authorDadgar, Farbod
dc.contributor.authorVenvik, Hilde Johnsen
dc.contributor.authorPfeifer, Peter
dc.date.accessioned2018-08-07T11:38:50Z
dc.date.available2018-08-07T11:38:50Z
dc.date.created2018-08-06T11:53:16Z
dc.date.issued2018
dc.identifier.citationChemical Engineering Science. 2018, 177 110-121.nb_NO
dc.identifier.issn0009-2509
dc.identifier.urihttp://hdl.handle.net/11250/2507872
dc.description.abstractThe knowledge of the flow distribution inside microstructured reactors is valuable e.g. for improving the reactor design, developing flow distributors, and optimizing the catalyst loading method. The applicability of the hot-wire anemometry (HWA) technique for experimental determination of the flow distribution inside a multi-stack micro-packed bed reactor is demonstrated for the first time. The anemometry data is then evaluated in relation to the reactor performance for methanol synthesis under relevant industrial operating conditions. A 400 µm long hot-wire connected to a constant temperature anemometer was applied for scanning the flow out of a specially designed reactor model, clamped on a motorized table equipped with a precise positioning system. The anemometry measurements revealed a nonuniformity in the catalyst packing, partially resulting from the reactor design. The flow distribution is poorer for smaller particles and for wider particle size distributions, and worsens as the superficial flow velocity (and the pressure drop) decreases. The effects of the packing nonuniformity on the reactor performance appear minor under methanol synthesis conditions. They could, however, turn out significant upon pushing the overall conversion in the whole reactor towards equilibrium as the synthesis reaction is exothermic, and temperature increase does alleviate the problem. The reactor design should be modified instead.nb_NO
dc.language.isoengnb_NO
dc.publisherElseviernb_NO
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/deed.no*
dc.titleApplication of hot-​wire anemometry for experimental investigation of flow distribution in micro-​packed bed reactors for synthesis gas conversionnb_NO
dc.typeJournal articlenb_NO
dc.typePeer reviewednb_NO
dc.description.versionacceptedVersionnb_NO
dc.source.pagenumber110-121nb_NO
dc.source.volume177nb_NO
dc.source.journalChemical Engineering Sciencenb_NO
dc.identifier.doi10.1016/j.ces.2017.10.039
dc.identifier.cristin1599885
dc.description.localcode© 2017. This is the authors’ accepted and refereed manuscript to the article. Locked until 19.12.2019 due to copyright restrictions. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/nb_NO
cristin.unitcode194,66,30,0
cristin.unitnameInstitutt for kjemisk prosessteknologi
cristin.ispublishedtrue
cristin.fulltextpostprint
cristin.qualitycode2


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Attribution-NonCommercial-NoDerivatives 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Attribution-NonCommercial-NoDerivatives 4.0 Internasjonal