Vis enkel innførsel

dc.contributor.authorRethy, Anna
dc.contributor.authorSæternes, Jørn Ove
dc.contributor.authorHalgunset, Jostein
dc.contributor.authorMårvik, Ronald
dc.contributor.authorHofstad, Erlend Fagertun
dc.contributor.authorSanchez-Margallo, Juan A.
dc.contributor.authorLangø, Thomas
dc.date.accessioned2018-02-20T15:36:01Z
dc.date.available2018-02-20T15:36:01Z
dc.date.created2017-10-26T12:25:38Z
dc.date.issued2017
dc.identifier.citationInternational Journal of Computer Assisted Radiology and Surgery. 2017, 13 (1), 61-72.nb_NO
dc.identifier.issn1861-6410
dc.identifier.urihttp://hdl.handle.net/11250/2486086
dc.description.abstractPurpose The objective of this study was to develop a multimodal, permanent liver phantom displaying functional vasculature and common pathologies, for teaching, training and equipment development in laparoscopic ultrasound and navigation. Methods Molten wax was injected simultaneously into the portal and hepatic veins of a human liver. Upon solidification of the wax, the surrounding liver tissue was dissolved, leaving a cast of the vessels. A connection was established between the two vascular trees by manually manipulating the wax. The cast was placed, along with different multimodal tumor models, in a liver shaped mold, which was subsequently filled with a polymer. After curing, the wax was melted and flushed out of the model, thereby establishing a system of interconnected channels, replicating the major vasculature of the original liver. Thus, a liquid can be circulated through the model in a way that closely mimics the natural blood flow. Results Both the tumor models, i.e., the metastatic tumors, hepatocellular carcinoma and benign cyst, and the vessels inside the liver model, were clearly visualized by all the three imaging modalities: CT, MR and ultrasound. Doppler ultrasound images of the vessels proved the blood flow functionality of the phantom. Conclusion By a two-step casting procedure, we produced a multimodal liver phantom, with open vascular channels, and tumor models, that is the next best thing to practicing imaging and guidance procedures in animals or humans. The technique is in principle applicable to any organ of the body.nb_NO
dc.language.isoengnb_NO
dc.publisherSpringernb_NO
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleAnthropomorphic liver phantom with flow for multimodal image-guided liver therapy research and trainingnb_NO
dc.typeJournal articlenb_NO
dc.typePeer reviewednb_NO
dc.description.versionpublishedVersionnb_NO
dc.source.pagenumber61-72nb_NO
dc.source.volume13nb_NO
dc.source.journalInternational Journal of Computer Assisted Radiology and Surgerynb_NO
dc.source.issue1nb_NO
dc.identifier.doi10.1007/s11548-017-1669-3
dc.identifier.cristin1507972
dc.description.localcode© The Author(s) 2017. This article is an open access publication.This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.nb_NO
cristin.unitcode194,65,15,0
cristin.unitnameInstitutt for klinisk og molekylær medisin
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse 4.0 Internasjonal