Show simple item record

dc.contributor.authorZisko, Nina
dc.contributor.authorCarlsen, Trude
dc.contributor.authorSalvesen, Øyvind
dc.contributor.authorAspvik, Nils Petter
dc.contributor.authorIngebrigtsen, Jan Erik
dc.contributor.authorWisløff, Ulrik
dc.contributor.authorStensvold, Dorthe
dc.date.accessioned2017-10-25T06:49:37Z
dc.date.available2017-10-25T06:49:37Z
dc.date.created2015-09-17T12:19:15Z
dc.date.issued2015
dc.identifier.issn1471-2318
dc.identifier.urihttp://hdl.handle.net/11250/2461980
dc.description.abstractBackground Public health initiatives world-wide recommend increasing physical activity (PA) to improve health. However, the dose and the intensity of PA producing the most benefit are still debated. Accurate assessment of PA is necessary in order to 1) investigate the dose–response relationship between PA and health, 2) shape the most beneficial public health initiatives and 3) test the effectiveness of such initiatives. Actigraph accelerometer is widely used to objectively assess PA, and the raw data is given in counts per unit time. Count-thresholds for low, moderate and vigorous PA are mostly based on absolute intensity. This leads to largely inadequate PA intensity assessment in a large proportion of the elderly, who due to their declining maximal oxygen uptake (VO2max) cannot reach the moderate/vigorous intensity as defined in absolute terms. To resolve this issue, here we report relative Actigraph intensity-thresholds for the elderly. Methods Submaximal-oxygen-uptake, VO2max and maximal heart rate (HRmax) were measured in 111 70–77 year olds, while wearing an Actigraph-GT3X+. Relationship between VO2max percentage (%), counts-per-minute (CPM) and gender (for both the vertical-axis (VA) and vector-magnitude (VM)) and VO2max% and HRmax% was established using a mixed-regression-model. VM-and VA-models were tested against each other to see which model predicts intensity of PA better. Results VO2max and gender significantly affected number of CPM at different PA intensities (p < 0.05). Therefore, intensity-thresholds were created for both men and women of ranging VO2max values (low, medium, high). VM-model was found to be a better predictor of PA-intensity than VA-model (p < 0.05). Established thresholds for moderate intensity (46−63 % of VO2max) ranged from 669–3367 and 834–4048 CPM and vigorous intensity (64−90 % of VO2max) from 1625–4868 and 2012-5423CPM, for women and men, respectively. Lastly, we used this evidence to derive a formula that predicts customized relative intensity of PA (either VO2max% or HRmax%) using counts-per-minute values as input. Conclusion Intensity-thresholds depend on VO2max, gender and Actigraph-axis. PA intensity-thresholds that take all these factors into account allow for more accurate relative intensity PA assessment in the elderly and will be useful in future PA research.nb_NO
dc.language.isoengnb_NO
dc.publisherBioMed Centralnb_NO
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleNew relative intensity ambulatory accelerometer thresholds for elderly men and women: The Generation 100 studynb_NO
dc.typeJournal articlenb_NO
dc.typePeer reviewednb_NO
dc.description.versionpublishedVersionnb_NO
dc.source.volume15nb_NO
dc.source.journalBMC Geriatricsnb_NO
dc.identifier.doi10.1186/s12877-015-0093-1
dc.identifier.cristin1265094
dc.description.localcode© 2015 Zisko et al. Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/)nb_NO
cristin.unitcode194,65,25,0
cristin.unitcode194,65,15,0
cristin.unitcode194,67,25,0
cristin.unitnameInstitutt for sirkulasjon og bildediagnostikk
cristin.unitnameInstitutt for klinisk og molekylær medisin
cristin.unitnameInstitutt for sosiologi og statsvitenskap
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Navngivelse 4.0 Internasjonal
Except where otherwise noted, this item's license is described as Navngivelse 4.0 Internasjonal