dc.description.abstract | Purpose: The authors have studied the accuracy and robustness of a prototype electromagnetic window field generator (WFG) in an interventional radiology suite with a robotic C-arm. The overall purpose is the development of guidance systems combining real-time imaging with tracking of flexible instruments for bronchoscopy, laparoscopic ultrasound, endoluminal surgery, endovascular therapy, and spinal surgery. Methods: The WFG has a torus shape, which facilitates x-ray imaging through its centre. The authors compared the performance of the WFG to that of a standard field generator (SFG) under the influence of the C-arm. Both accuracy and robustness measurements were performed with the C-arm in different positions and poses. Results: The system was deemed robust for both field generators, but the accuracy was notably influenced as the C-arm was moved into the electromagnetic field. The SFG provided a smaller root-mean-square position error but was more influenced by the C-arm than the WFG. The WFG also produced smaller maximum and variance of the error. Conclusions: Electromagnetic (EM) tracking with the new WFG during C-arm based fluoroscopy guidance seems to be a step forward, and with a correction scheme implemented it should be feasible. | nb_NO |
dc.language.iso | eng | nb_NO |
dc.title | Accuracy of electromagnetic tracking with a prototype field generator in an interventional OR setting | nb_NO |
dc.type | Journal article | nb_NO |
dc.type | Peer reviewed | nb_NO |
dc.source.pagenumber | 399-406 | nb_NO |
dc.source.volume | 39 | nb_NO |
dc.source.journal | Medical physics (Lancaster) | nb_NO |
dc.source.issue | 1 | nb_NO |
dc.identifier.doi | 10.1118/1.3666768 | |
dc.identifier.cristin | 878636 | |
dc.description.localcode | © 2012 American Association of Physicists in Medicine. This is the authors' accepted and refereed manuscript to the article. | nb_NO |
cristin.unitcode | 194,65,25,0 | |
cristin.unitname | Institutt for sirkulasjon og bildediagnostikk | |
cristin.ispublished | true | |
cristin.fulltext | postprint | |
cristin.qualitycode | 1 | |