Show simple item record

dc.contributor.authorStruksnæs, Camilla
dc.contributor.authorBlaas, Harm-Gerd Karl
dc.contributor.authorEik-Nes, Sturla
dc.contributor.authorVogt, Christina
dc.date.accessioned2017-01-26T14:59:26Z
dc.date.available2017-01-26T14:59:26Z
dc.date.created2016-01-06T11:52:21Z
dc.date.issued2016
dc.identifier.citationUltrasound in Obstetrics and Gynecology. 2016, 48 (2), 232-238.nb_NO
dc.identifier.issn0960-7692
dc.identifier.urihttp://hdl.handle.net/11250/2428690
dc.description.abstractObjective: A prenatal ultrasound examination and a postmortem examination provide the basis for correct diagnosis in fetuses terminated due to congenital anomalies. The aim of this study was to correlate fetal anomalies detected by ultrasound examination with those identified at autopsy following termination of pregnancy (TOP) over a 30-year period, and to evaluate the correlation between findings at different gestational ages and assess these trends over time. Methods: The study group consisted of 1029 TOPs performed over a 30-year period, from 1985 to 2014. The gestational age ranged between 11 and 33 weeks. Prenatal ultrasound examinations were performed at the National Center for Fetal Medicine, St Olavs Hospital, Trondheim, Norway. Autopsies were performed at the Department of Pathology and Medical Genetics at the same hospital or a collaborating hospital. Results: There was full agreement between ultrasound and autopsy findings in 88.1% (907/1029) of TOPs, and the main diagnosis was correct in 97.9% (1007/1029). When comparing the 15-year period of 2000–2014 with that of 1985–1999, the difference in the rates of full agreement and agreement in the main diagnosis was statistically significant. In 1.3% (13/1029) of cases, ultrasound findings were not confirmed at autopsy. There were no false-positive diagnoses leading to TOP. Throughout the 30-year period, there was an increase in early TOPs, whereas late TOPs declined. Conclusions: Our study demonstrates that there is a clear correlation between ultrasound and autopsy findings, which is continuously improving. Despite this high correlation, there is reason to continue the practice of validation to ensure the safety of the diagnostic process leading to TOP. The trend towards an earlier termination emphasizes the necessity of such a practice.nb_NO
dc.language.isoengnb_NO
dc.publisherWileynb_NO
dc.titleCorrelation between prenatal ultrasound and postmortem findings in 1029 fetuses following termination of pregnancynb_NO
dc.typeJournal articlenb_NO
dc.typePeer reviewednb_NO
dc.source.pagenumber232-238nb_NO
dc.source.volume48nb_NO
dc.source.journalUltrasound in Obstetrics and Gynecologynb_NO
dc.source.issue2nb_NO
dc.identifier.doi10.1002/uog.15773
dc.identifier.cristin1306916
dc.description.localcode© 2015 ISUOG. Published by John Wiley & Sons Ltd. This is the authors' accepted and refereed manuscript to the article, postprint.nb_NO
cristin.unitcode194,65,10,0
cristin.unitnameInstitutt for laboratoriemedisin, barne- og kvinnesykdommer
cristin.ispublishedtrue
cristin.fulltextpostprint
cristin.qualitycode2


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record