Show simple item record

dc.contributor.authorTime, Berit
dc.contributor.authorUvsløkk, Sivert
dc.contributor.authorPlsek, Dalibor
dc.contributor.authorGustavsen, Arild
dc.contributor.authorAsphaug, Silje
dc.date.accessioned2016-01-08T12:16:40Z
dc.date.accessioned2016-03-07T14:18:40Z
dc.date.available2016-01-08T12:16:40Z
dc.date.available2016-03-07T14:18:40Z
dc.date.issued2015
dc.identifier.citationEnergy Procedia 2015, 78:2482-2487nb_NO
dc.identifier.issn1876-6102
dc.identifier.urihttp://hdl.handle.net/11250/2381697
dc.description.abstractThere is an increasing interest in development of coupled multi-layer window structures. This is to optimize thermal properties and to develop systems with a better climate protected solar shading system. The risk of condensation on the inside of the exterior glass layer in a multi-layer window structure might be a challenge and is often questioned. The risk of condensation will depend on both window properties and indoor and outdoor climate conditions. The air gap between the inner and outer part have to be ventilated with outdoor air to give the window a “drying out” capacity. The U-value of the window and the moisture condition in the air gap both depend on the ventilation of the air gap. Reducing the ventilation improves the U-value, but increases the time of desiccation.Net long-wave radiation from the glass surface to the atmosphere during cloudless night-time will cause exterior glass temperatures lower than the outdoor air temperature, and hence increase the risk of condensation on both sides of the exterior glass. The aim of this work has been to assess for which climate conditions there will be a risk of condensation on the exterior glass layer and what might be the optimal ventilation of the outermost air gap. Simulations of the temperature on the exterior surface of the glazing including the long-wave radiation during night- time have been done and compared to measurements. An assessment has been made studying the risk of condensation and the drying out rate for climate conditions for two locations in Germany. A spreadsheet-based model calculating the U-value of a multilayer glazing unit according to ISO 15099 [1] has been further developed including airflow from exterior openings through the air gap.nb_NO
dc.language.isoengnb_NO
dc.publisherElseviernb_NO
dc.titleMoisture in Multi-Layer Windowsnb_NO
dc.typePeer reviewednb_NO
dc.typeJournal articleen_GB
dc.date.updated2016-01-08T12:16:40Z
dc.source.volume78nb_NO
dc.source.journalEnergy Procedianb_NO
dc.identifier.doi10.1016/j.egypro.2015.11.233
dc.identifier.cristin1308665
dc.description.localcode© 2016 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license.nb_NO


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record