dc.description.abstractUsing energy simulation software this report studies a typical Norwegian commercial buildings thermal energy loss. The buildings energy use is simulated and analyzed using SIMIEN, for four levels of thermal resistance in the building envelope. Resulting savings in electricity bills is calculated. Alternative wall-, floor- and roofing solutions with state-of-the-art insulation materials will be chosen based on U-values, prices and availability on the Norwegian market. A conclusion on the most profitable energy saving measure will be made based on these findings.nb_NO
dc.languageengnb_NO
dc.publisherInstitutt for bygg, anlegg og transportnb_NO
dc.titleCost effectiveness of higher thermal resistance in commercial buildingsnb_NO
dc.typeMaster thesisnb_NO
dc.source.pagenumber77nb_NO
dc.contributor.departmentNorges teknisk-naturvitenskapelige universitet, Fakultet for ingeniørvitenskap og teknologi, Institutt for bygg, anlegg og transportnb_NO