Vis enkel innførsel

dc.contributor.authorKuhn, Wolf Ludwig
dc.contributor.authorSolemslie, Bjørn Winther
dc.contributor.authorHihn, Jean-Yves
dc.contributor.authorDahlhaug, Ole Gunnar
dc.date.accessioned2023-12-05T10:25:37Z
dc.date.available2023-12-05T10:25:37Z
dc.date.created2023-12-04T13:18:01Z
dc.date.issued2023
dc.identifier.issn1742-6588
dc.identifier.urihttps://hdl.handle.net/11250/3105999
dc.description.abstractIn Norway, a recent project used a risk matrix to identify about 200 hydropower plants ( 11 % of the total number) of being in high risk of producing air-supersaturated water. The combined installed capacity of these hydropower plants amounts to more than 45 % of Norway's total installed hydropower capacity. Total dissolved gas (TDG) supersaturation in water is, dependent on the actual saturation value and the duration of the occurrence, lethal to certain types of fish and aquatic invertebrates. Natural degassing is highly dependent on the morphology of the downstream water system, but tends to be insufficiently slow with regard to lethality of TDG supersaturation. The Brokke power plant in southern Norway is known to create TDG supersaturation. Since 2012, continuous monitoring of the TDG level happens at the power plant outlet and several positions in the Otra river downstream. Measurement data has been evaluated and a method has been developed to calculate the liquid-gas mass transfer coefficient kLa as an indicator for the natural degassing efficiency within certain stretches of the river using assumptions for the river's geometry. The results are in agreement with former evaluation of the measurements. At the Waterpower Laboratory at NTNU in Trondheim, Norway, a test rig has been designed and instrumented to prove the effectiveness of degassing methods. An in-house pressure system is used to produce air-supersaturated water, which is then channeled through an open flume. At the flume's inlet, the degassing mechanism is installed. The TDG levels are monitored both upstream and at downstream the degassing device. The kLa will be used to compare natural degassing in the river downstream Brokke power plant to the experimental degassing methods in the Waterpower Laboratory.en_US
dc.language.isoengen_US
dc.publisherIOP Publishingen_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleEvaluating natural degassing in a river to create a baseline for comparison to technical degassing methods.en_US
dc.title.alternativeEvaluating natural degassing in a river to create a baseline for comparison to technical degassing methods.en_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.source.volume2629en_US
dc.source.journalJournal of Physics: Conference Series (JPCS)en_US
dc.source.issue012032en_US
dc.identifier.doi10.1088/1742-6596/2629/1/012032
dc.identifier.cristin2208473
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse 4.0 Internasjonal