Show simple item record

dc.contributor.advisorGossé, Sigurd
dc.contributor.advisorBudde, Anders
dc.contributor.authorPedersen, Vetle
dc.contributor.authorSelnes, Markus
dc.contributor.authorLegkikh, Anatolii
dc.date.accessioned2023-07-11T17:28:04Z
dc.date.available2023-07-11T17:28:04Z
dc.date.issued2023
dc.identifierno.ntnu:inspera:146719425:149875481
dc.identifier.urihttps://hdl.handle.net/11250/3078030
dc.description.abstractDenne oppgaven har vi kartlagt og undersøkt problemene ved Galtneset, et vannbehandlingsanlegg som bruker teknologien omvendt osmose for å produsere drikkvann fra sjøvann. Anlegget er eid og driftes av Træna kommune. Problemene som vi har undersøkt omhandler driftsstopp på grunn av alarmen som utløses av ulike årsaker. Kommunens ansatte mener at problemene er fremtrendene ved gitte situasjoner. Eksempelvis mener de at sjøvannspumpen stopper når tidevannet er lavt eller når Pelagia, en fabrikk som bearbeider matfisk, bruker sine sjøvannspumper til å produsere eget rentvann. Hovedproblemet er altså at inntakskummen for sjøvannspumpene er plassert for høyt i forhold til havnivået og at Pelagia og kommuen deler inntakskum og inntaksledning. I tillegg er anleggets dokumentasjon er mangelfull og det finnes ingen god totaloversikt noe som gjør arbeidet ved anlegget vanskelig. Med dette utgangspunktet har vi arbeidet med å skaffe en god oversikt over anleggets komponenter ved bruk av gamle dokumenter som tilhører anlegget og dialog med teknisk ansatte i kommunen. Arbeidet har vært metodisk og analytisk for å samle all relevant informasjon. Anlegget styres og overvåkes ved bruk av PLS. Det har heller ikke vært noen god dokumentasjon og oversikt over programkoden. Derfor har det vært en viktig del av arbeid å skaffe oversikt over denne. Styresystemet er gammelt og utdatert, og det finnes ingen vedlikeholdsavtale for å støtte kommuen om det skulle slutte å fungere. Det vil i ytterste konsekvens bety at anlegget ikke kan produsere drikkevann hvis PLS skulle slutte å fungere. Det er benyttet dataanalyse for å undersøke problemene som kommunen beskriver som årsak til alarmutløsning. Ved å bruke historiske data fra anlegget og sammenligne dette med alarmutløsningstidspunkt så kan vi se om problemene kan årsaksforklares med påstandene fra kommunen. Vi har også undersøkt mulige endringer på dagens produksjonsmåte. For det viser seg at anleggets dimensjonering er idag for stor i forhold til etterspørsel av vann. Derfor har vi kommet med et forslag til løsning som kan videreutvikles. Forslaget går ut på å montere ventiler i sammenheng med hver av de seks membranene som brukes for å skille saltet fra vannet. På denne måten kan produksjonsmengden reguleres ut i fra etterspørsel. Vi har nå lagt grunnlaget for videre arbeid og utvikling av Galtneset VBA, med flere spennende problemstillinger å ta fatt på.
dc.description.abstractWe have surveyed and investigated the issues at Galtneset, a water treatment plant that utilizes reverse osmosis technology to produce drinking water from seawater. The facility is owned and operated by Træna municipality. The problems we have examined revolve around operational shutdowns triggered by various alarms. The municipality employees believes that these issues arise under specific circumstances. For example, they believe that the seawater pump stops when the tide is low or when Pelagia AS, a fish food factory, uses its seawater pumps to produce water for their own fish food production. The main problem is that the intake well for the seawater pumps is positioned too high relative to sea level, and Pelagia and the municipality share the same intake well and intake pipeline. Additionally, the documentation of the facility is inadequate, and there is no comprehensive overview, making the work at the facility challenging. Based on this background, we have worked towards gaining a comprehensive understanding of the components of the facility by using old documents associated with the plant and engaging in discussions with the technical staff at the municipality. The work has been systematic and analytical, aiming to gather all relevant information. The facility is controlled and monitored using a PLC. However, there is also a lack of proper documentation and overview of the program code. Therefore, an important part of the work has been to gain an understanding of it. The control system is old and outdated, and there is no maintenance agreement in place to support the municipality if it were to stop functioning. In the worst-case scenario, this would mean that the plant cannot produce drinking water if the PLC ceases to operate. Data analysis has been utilized to investigate the issues that the municipality describes as the cause of alarm triggers. By using historical data from the facility and comparing it with the times when alarms were triggered, we can determine if the problems can be explained by the municipality's claims. We have also explored possible changes to the current production methods. It turns out that the facility's capacity is currently too large compared to the water demand. Therefore, we have proposed a solution that can be further developed, which involves installing valves in connection with each of the six membranes used to separate salt from water. This way, the production quantity can be regulated based on demand. We have now laid the foundation for further work and development of the Galtneset water treatment plant, with several intriguing issues to address.
dc.languagenob
dc.publisherNTNU
dc.titleUndersøkelser og kartlegging av utfordringer ved Galtneset VBA
dc.typeBachelor thesis