dc.description.abstractDet nåværende utstyret på St. Olavs hospital som blir brukt til å diagnostisere Exercise Induced laryngeal obstruction (EILO) ved hjelp av Continuous Larynx Examination (CLE), har flere utbredte problemer. En riktig EILO diagnose krever at legene kan se abnormiteter i pasientens strupehode under anstrengende trening. Dette gjøres ved å føre et tynt endoskopkamera gjennom nesehulen til endoskopet når et punkt hvor det har en direkte siktlinje til strupehodet og stemmebåndene. Det nåværende utstyret klarer noen ganger ikke å gi tilstrekkelig informasjon til legene på grunn av opptakenes ustabilitet og mangel på klarhet. I tillegg er det nåværende oppsettet for å sette endoskopet på plass under trening upålitelig og ubehagelig, og har en tendens til å mislykkes under testen, noe som fører til at testen må startes på nytt. Det er også et vanskelig og tidkrevende oppsett, som fører til at legene drastisk reduserer antallet CLE-testprosedyrer som utføres. Ved fordypning i de utbredte forbedringsområdene, og ved bruk av eksisterende forskning fra studier, artikler og journaler, i tillegg til kommunikasjon med legene ved St. Olavs hospital, vil denne bacheloroppgaven presentere en rekke ulike mulige konsepter som kan implementeres som løsninger til de aktuelle problemstillingene. Oppgaven evaluerer også disse konseptene for å finne ut hvilke konsept som er mest effektivt å teste og implementere innenfor oppgavens omfang. Som et resultat ble det utviklet bedre utstyr for å holde endoskopet på plass, bildestabiliteten og klarheten ble forbedret, oppsetts tiden ble drastisk redusert og pasientens komfort ble økt. I tillegg ble det gitt ytterligere forskningsområder som kun ble undersøkt på overflatenivå på grunn av begrensningene i denne oppgaven.
dc.description.abstractThe current equipment at St. Olavs hospital used to diagnose Exercise Induced Laryngeal Obstruction (EILO) with the help of a Continuous Larynx Examination (CLE), suffers from several prevalent problems. A proper EILO diagnosis requires physicians to be able to see abnormalities within the patient’s larynx during strenuous exercise. This is done by inserting a thin endoscope camera through the nasal cavity until the endoscope reaches a point where it has a direct line of sight of the larynx and the vocal cords. The current equipment sometimes fails to provide sufficient information to the physicians due to the footage’s instability and lack of clarity. Additionally, the current setup to hold the endoscope in place during exercise is unreliable and uncomfortable, and tends to fail during the test, causing the test to be restarted. It is also a difficult and time-consuming setup, which causes the physicians to drastically reduce the amount of CLE-test procedures performed. Delving into the prevalent areas of improvement, and using existing research from studies, articles, and journals, in addition to communicating with the physicians at St. Olavs hospital, this bachelor thesis presents a variety of different possible concepts, that could be implemented as solutions to the current issues. It also evaluates these concepts, to determine which are the most effective to test and implement within the scope of the thesis. As a result, better setup equipment for holding the endoscope in place was developed, footage stability and clarity were improved, the setup-time was drastically reduced and the patient’s comfort was increased. Additionally, further research areas were provided, that were only investigated on a surface level due to the limitations of this thesis.
dc.languageeng
dc.publisherNTNU
dc.titleImprovement of Continuous Larynx Examination test equipment