dc.contributor.authorSkirbekk, Fanny
dc.contributor.authorMauseth, Frank
dc.contributor.authorMeyer, Hans Kristian Hygen
dc.date.accessioned2023-03-24T08:43:06Z
dc.date.available2023-03-24T08:43:06Z
dc.date.created2022-12-06T15:45:19Z
dc.date.issued2022
dc.identifier.issn2535-3969
dc.identifier.urihttps://hdl.handle.net/11250/3060249
dc.description.abstractalternatives to the potent greenhouse gas SF6 in medium voltage (MV) gas insulated switchgear. MV products using this gas mixture are already commercially available, but there is still a lack of knowledge about this gas mixture especially regarding pre-breakdown phenomena. In this study, positive and negative streamers are studied in technical air with 7.5 %vol C5-FK at 1.0, 1.3, and 1.5 bar (absolute pressure). Similar tests were done in technical air (80% N2, 20% O2) for comparison with the C5-FK results. The streamers emerged from a grounded needle electrode placed 53mm below a planar electrode. The electrode setup was stressed by a non-standard lightning impulse voltage with voltage peaks varying from 52 to 129 kV. A photomultiplier tube (PMT) was used to register the streamers, and an iCCD camera was used to image the streamers. The pre-breakdown phenomena in C5-FK+air were found to be shorter, less than 1/5 of the length, and to branch less than in pure technical air. The streamer branches in both gas mixtures became wider and less clear when the pressure was decreased. Leader-like channels were observed for C5-FK+air at 1.5 bar (both polarities) and at 1.3 bar (negative streamers).en_US
dc.description.abstractPre-Breakdown Phenomena in Technical Air with and without C5-Fluoroketone for a Rod-Plane Gapen_US
dc.language.isoengen_US
dc.publisherNORD-ISen_US
dc.relation.urihttps://www.ntnu.no/ojs/index.php/nordis/article/view/4553
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titlePre-Breakdown Phenomena in Technical Air with and without C5-Fluoroketone for a Rod-Plane Gapen_US
dc.title.alternativePre-Breakdown Phenomena in Technical Air with and without C5-Fluoroketone for a Rod-Plane Gapen_US
dc.typeJournal articleen_US
dc.typePeer revieweden_US
dc.description.versionpublishedVersionen_US
dc.source.volume27en_US
dc.source.journalProceedings of the Nordic Insulation Symposiumen_US
dc.source.issue1en_US
dc.identifier.doi10.5324/nordis.v27i1.4553
dc.identifier.cristin2089597
dc.relation.projectNorges forskningsråd: 323328en_US
dc.relation.projectNorges forskningsråd: 319930en_US
cristin.ispublishedtrue
cristin.qualitycode1


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Navngivelse 4.0 Internasjonal
Except where otherwise noted, this item's license is described as Navngivelse 4.0 Internasjonal