Show simple item record

dc.contributor.authorObradovic, Biljana
dc.contributor.authorMatusiak, Barbara Szybinska
dc.date.accessioned2023-03-01T13:09:33Z
dc.date.available2023-03-01T13:09:33Z
dc.date.created2022-12-14T15:08:55Z
dc.date.issued2022
dc.identifier.citationJournal of Daylighting. 2022, 9 209-227.en_US
dc.identifier.issn2383-8701
dc.identifier.urihttps://hdl.handle.net/11250/3055023
dc.description.abstractThis paper describes a field study of the illumination and lighting energy use in a full-scale test office in a building located in southern Norway. Natural light is provided to the office via southwest-oriented windows and a horizontal light pipe (HLP) with a daylight entrance facing the south. The study is a full-scale field study, and it is a continuation of the recently published study addressing a scale model and a theoretical model. The novelty of this study is a custom-made reflector for the HLP’s daylight distribution to preserve the features of natural light noted as the primary human association with daylight. The main research aim was to determine if the daylighting level in the back of the office was improved as a consequence of the daylighting provision from the HLP compared to a reference situation without a HLP, as well as whether the lighting energy use for the electric lighting system that was supposed to provide the recommended light level was reduced. This study includes monitoring of the outdoor and indoor illuminance levels as well as the energy consumption of the luminaires throughout the study’s test period and a corresponding reference period. The recorded data were used to test hypothesis applying inferential statistical analyses. In conclusion, this paper reports an increased daylight level on the working area in the rear part of the office of approximately 200 to 300 lx during clear and sunny days at equinox. The increased daylight level on the working area near the window of approximately 50 lx was also recorded. These findings have important implications for energy balance in the Zero Energy Buildings (ZEB) and the ‘peak load’ for energy consumption.en_US
dc.language.isoengen_US
dc.publisherSolarlitsen_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleIllumination and Lighting Energy Use in an Office Room with a Horizontal Light Pipe: Field Study at a High Latitudeen_US
dc.title.alternativeIllumination and Lighting Energy Use in an Office Room with a Horizontal Light Pipe: Field Study at a High Latitudeen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.source.pagenumber209-227en_US
dc.source.volume9en_US
dc.source.journalJournal of Daylightingen_US
dc.identifier.doi10.15627/jd.2022.16
dc.identifier.cristin2093277
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Navngivelse 4.0 Internasjonal
Except where otherwise noted, this item's license is described as Navngivelse 4.0 Internasjonal