Show simple item record

dc.contributor.advisorGeving, Stig
dc.contributor.advisorGullbrekken, Lars
dc.contributor.authorHummelsund, Henrik Crook
dc.date.accessioned2021-10-05T17:41:11Z
dc.date.available2021-10-05T17:41:11Z
dc.date.issued2021
dc.identifierno.ntnu:inspera:80590524:15640164
dc.identifier.urihttps://hdl.handle.net/11250/2787929
dc.description.abstractEtter andre verdenskrig ble det bygget mange småhus som i dag er regnet som dårlig varmeisolerte. Disse har behov for en oppgradering for å møte dagens behov for energieffektivitet. Gjennom forskningsprosjektet OPPTRE blir nye løsninger for energioppgradering av småhus undersøkt, hvor blant annet fuktsikkerhet er i fokus. Tradisjonelt har skrå luftede tak hatt behov for et dampåpent sjikt mot uteluften for å kunne tørke. Med smart dampsperre er fukttransport mot inneluften mulig, noe som åpner for nye muligheter og løsninger som tidligere ikke har vært mulig uten høy risiko for fuktskader og muggsopp. I denne oppgaven er en løsning for etterisolering av skrå luftede tak i småhus ved bruk av smart dampsperre undersøkt. Med utgangspunkt i saltak fra 1950 til 1980 er løsningen mindre arbeidskrevende enn anbefalte etterisoleringsløsninger, samt at nedfôring av himlingen mot innsiden kan bli redusert. Oppgaven er gjennomført som en parameterundersøkelse, med beregninger av takkonstruksjonen i beregningsprogrammet for fukt- og varmetransport, WUFI 2D. Tilleggsprogrammet WUFI Mould Index VTT er også benyttet for beregning av muggvekst. Et utvalg parametere som varierer fra bolig til bolig, og som er antatt til å ha effekt på takets uttørkingsevne eller risiko for muggvekst er variert i beregningene. Resultatene av parameterundersøkelsen viser at det hovedsakelig er en utfordring å få høyt nok varmebidrag fra kortbølget stråling, for at taket skal få god nok uttørkingsevne. Orientering, takhelling og geografisk posisjon påvirker kortbølget strålingsintensitet på takflaten, og absorptansen for solstråling påvirker hvor stort varmebidraget fra strålingen blir. Med lavt varmebidrag akkumulerer fukt i taket uten mulighet for å tørke ut. Med høyt varmebidrag kan uttørkingseffekten også kompensere for andre ugunstige effekter. Dersom man forutsetter lav byggfukt og lavt fukttilskudd kan konstruksjonen være gunstig i mange forhold. Konservativ orientering av takflaten mot nord har da tilstrekkelig uttørkingsevne i nesten hele Norge. Dersom man lukker taket tidig på sommeren kan taket også tåle høyere nivåer av startfukt. Tre smart dampsperre-produkter er også undersøkt, hvor den største forskjellen på dem er funnet til å være uttørkingsevnen på sommeren. AirGuard Smart har best uttørkingsevne for alle beregninger som er sammenlignet med de to andre smarte dampsperrene, Majrex og Intello. Ved sammenligning med en takoppbygging med tradisjonell dampsperre og dampåpent undertak, er den tradisjonelle løsningen mer robust for byggfukt og høyt fukttilskudd enn løsningen med smart dampsperre. Dette ser man ved at den tradisjonelle takoppbyggingen har raskere uttørkingstid og tørker til et lavere totalt fuktinnhold. Den tradisjonelle takoppbyggingen fremstår også som mer robust ved at den ikke avhengig av varmebidrag fra kortbølget stråling.
dc.description.abstractAfter the Second World War, many small houses were built which today are considered poorly heat insulated. These need an upgrade to meet the current need for energy efficiency. Through the research project OPPTRE, new solutions for energy upgrading of wooden dwellings are investigated, where, among other things, moisture safety is in focus. Traditionally, pitched ventilated roofs have needed a vapor-open layer against the outdoor air to be able to dry. With a smart vapor barrier, moisture transport to the indoor air is possible, which enables new possibilities and solutions that have not previously been possible without a high risk of moisture damage and mould growth. In this thesis, a solution for retrofitting pitched ventilated roofs in wooden dwellings using a smart vapor barrier has been investigated. Based on gable roofs from 1950 to 1980, the solution needs less work than recommended retrofitting solutions, and the lowering of the ceiling to the inside can be reduced. The thesis has been carried out as a parameter study, with calculations of the roof structure in the hygrothermal simulation tool, WUFI 2D. The add-on WUFI Mould Index VTT is also used for calculating mould growth. A selection of parameters that varies in dwellings, and which are assumed to have an effect on the roof's drying ability or risk of mold growth, are varied in the calculations. The results of the parameter study show that it is mainly a challenge to get a high enough heat contribution from short-wave radiation, for the roof to have good enough drying ability. Orientation, roof slope and geographical position affect the short-wave radiation intensity on the roof surface, and the absorption for solar radiation affects how large the heat contribution from the radiation is. With a low heat contribution, moisture accumulates in the roof without the possibility of drying out. With a high heat contribution, the drying effect can also compensate for other adverse effects. If one assumes low embedded moisture and low moisture excess, the construction can be favorable in many conditions. Conservative orientation of the roof surface to the north then has sufficient drying ability in almost all of Norway. If you close the roof early in the summer, the roof can also withstand higher levels of starting moisture. Three smart vapor barrier products have also been investigated, where the biggest difference between them has been found to be the drying ability in the summer. AirGuard Smart has the best drying ability for all calculations compared to the other two smart vapor barriers, Majrex and Intello. When compared with a roof structure with a traditional vapor barrier and a vapor-open sub-roof, the traditional solution is more robust for embedded moisture and high moisture excess than the solution with a smart vapor barrier. This can be seen in the fact that the traditional roof structure has a faster drying time and dries to a lower total moisture content. The traditional roof construction also appears to be more robust in that it does not depend on heat contributions from short-wave radiation.
dc.languagenob
dc.publisherNTNU
dc.titleEtterisolering av skrå tak i småhus ved bruk av smart dampsperre
dc.typeMaster thesis


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record