Vis enkel innførsel

dc.contributor.authorMazzanti, Giovanni
dc.contributor.authorCastellon, Jerome
dc.contributor.authorChen, George
dc.contributor.authorFothergill, John
dc.contributor.authorFu, M
dc.contributor.authorHozumi, Naohiro
dc.contributor.authorLee, J.H.
dc.contributor.authorLi, Jianying
dc.contributor.authorMarzinotto, Massimo
dc.contributor.authorMauseth, Frank
dc.contributor.authorMorshuis, Peter
dc.contributor.authorReed, Clive
dc.contributor.authorTroia, Ivan
dc.contributor.authorTzimas, Antonios
dc.contributor.authorWu, K.
dc.date.accessioned2019-06-05T06:47:04Z
dc.date.available2019-06-05T06:47:04Z
dc.date.created2019-05-30T12:56:01Z
dc.date.issued2019
dc.identifier.citationIEEE transactions on dielectrics and electrical insulation. 2019, 26 (3), 973-980.nb_NO
dc.identifier.issn1070-9878
dc.identifier.urihttp://hdl.handle.net/11250/2599945
dc.description.abstractThe review of materials, design and testing of joints for HVDC extruded cable systems provided in previous Part 1 paved the way to this Part 2 position paper by the DEIS HVDC Cable Systems Technical Committee, whose aim is to remedy the scarcity of existing standardized tests on joints. After a sound analysis, here routine tests are identified as the first practical target for the onset of new testing procedures, AC-PD measurements as the readily-available measurement from manufacturers' experience for quality control of joints during routine tests and VHF/UHF wireless sensors as the best tool for such measurements in the noisy environment of factories. Thereby, a novel protocol for PD measurement using AC voltages and VHF/UHF electromagnetic sensors, for quality control during routine tests on HVDC extruded joints, is proposed.nb_NO
dc.description.abstractThe insulation of HVDC extruded cable system joints. Part 2: Proposal of a new AC voltage PD measurement protocol for quality control during routine testsnb_NO
dc.language.isoengnb_NO
dc.publisherInstitute of Electrical and Electronics Engineers (IEEE)nb_NO
dc.titleThe insulation of HVDC extruded cable system joints. Part 2: Proposal of a new AC voltage PD measurement protocol for quality control during routine testsnb_NO
dc.typeJournal articlenb_NO
dc.typePeer reviewednb_NO
dc.description.versionacceptedVersionnb_NO
dc.source.pagenumber973-980nb_NO
dc.source.volume26nb_NO
dc.source.journalIEEE transactions on dielectrics and electrical insulationnb_NO
dc.source.issue3nb_NO
dc.identifier.doi10.1109/TDEI.2019.8726047
dc.identifier.cristin1701567
dc.description.localcode© 2019 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.nb_NO
cristin.unitcode194,63,20,0
cristin.unitnameInstitutt for elkraftteknikk
cristin.ispublishedtrue
cristin.fulltextpostprint
cristin.qualitycode2


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel